Evaluasi perpindahan panas dan efisiensi superheater pada unit multi fuel boiler

J.R.H. Panjaitan, J.S. Sihotang, K.M. Sirait, R. Pakpaha

Abstract


The heat exchanger was used to carry out the heat exchange process between two fluids. One of the heat exchangers is the Multi Fuel Boiler. In multi-fuel boilers, there was a superheater which functions to convert saturated steam into dry steam. In this research, the evaluation of superheater heat transfer efficiency in Multi Fuel Boiler Units will be studied. The results showed that the highest heat transfer coefficient for the superheater was on day 6 at 141,942.81 W/m2K with 56.51% efficiency. Meanwhile, the highest superheater efficiency was 58.72% on day-7 with the heat transfer coefficient being 130,755.76 W/m2K. Factors such as steam temperature, flue gas temperature, steam and flue gas flow rate, heat transfer area and soot blower influence the heat transfer coefficient and efficiency of the superheater.


Keywords


Boiler; Heat exchanger; Superheater

Full Text:

PDF

References


Adrian, J., Noerochim, L., Kurniawan, B.A., Analisa kerusakan superheater tube boiler tipe ASTM A213 grade T11 pada pembangkit listrik tenaga uap, Jurnal Teknik ITS, 5(2), 148 – 151, 2016.

Akbar, S., Nursyifaulkhair, D., Nurdiwijayanto, L., Noviyanto, A., Rochman, N.T., High-temperature failure of steel boiler tube secondary superheater in a power plant, Sinergi, 27(1), 1 – 6, 2023.

Endriyana, V.W., Ichsani, D., Analisis unjuk kerja secondary superheater PLTGU dan evaluasi peluang peningkatan effectiveness dengan cara variasi jarak, jumlah dan diameter tube, Jurnal Teknik Pomits, 2(3), 388 – 391, 2013.

Fitriana, S.L., Arini, N.R., Fadilah, W.N., Studi numerik pengaruh fouling terhadap peforma superheater dengan metode CFD. Seminar Nasional Terapan Riset Inovatif (SENTRINOV) ke-VII, 7(1), 303 – 310, 2021.

Gupta, G.K., Chattopadhyaya, S., Critical failure analysis of superheater tubes of coal-based boiler. Journal of Mechanical Engineering, 63(5), 287 – 299, 2017.

Harini, Analisis perhitungan laju perpindahan panas alat penukar kalor type pipa ganda di laboratorium Universitas 17 Agustus 1945 Jakarta, Jurnal Konversi Energi dan Manufaktur, 4(2), 51–61, 2017.

Juniarzal, F. K., Ridwan, E., Ulfiana, A., Analisis perbandingan heat exchanger jenis shell and tube dan plate pada ST, Seminar Nasional Teknik Mesin Politeknik Negeri Jakarta, 568 – 570, 2018.

Kern, D.Q., Process heat transfer, International Student Edition, McGraw-Hill Book Co., New York, 1996.

Kharisma, A.A., Perancangan heat exchanger tipe shell dan tube secara metode matematis dan simulasi software, Jurnal Rekayasa Mesin, 20(2), 27 – 30, 2020.

Moelbak, T., Advance control of superheater steam temperatures – an evaluation based on practical applications, Control Engineering Practice, 7, 1 – 10, 1999.

Mukhlis, Munir, M.M., Ari, M., K, H.B., R, I.K., Analisa kegagalan superheater tube boiler berpelapis baja tahan karat pendekatan metalografi dan komposisi kimia, Seminar Master, 4(1), 253 – 256, 2019.

Ningsih, T.H., Fiveriati, A., Ghoni, A., Proses produksi superheater tube yoshimin boiler H-3500 tipe CAP120T/H. Otopro, 14(1), 35 – 38, 2018.

Nugroho, S., Sulardjaka, Hadid, G.A., Failure analysis on pipeline welded joint of venting isolation high pressure superheater tube, Prosiding SNTTM XVI, 81 – 86, 2017.

Purnamasari, H.N., Kurniawan, T., Nandiyanto, A.B.D., Design of shell and tube type heat exchanger for nanofibril cellulose production process. International Journal of Research and Applied Technology, 1(2), 318 – 329, 2021.

Putra, I. Studi perhitungan heat exchanger type shell and tube dehumidifier biogas limbah sawit untuk pembangkit listrik tenaga biogas, Jurnal Polimesin, 12(2), 42 – 45, 2017.

Rasyid, R. F., Prajogo, S., Syafitri, A., Perancangan heat exchanger tipe shell and tube menggunakan helical baffles pada proses gasifikasi batu bara kapasitas 30000 Nm3/h, Prosiding The 13th Industrial Research Workshop and National Seminar, 830 – 833, 2021.

Rusnaldy, Tauviqirrahman, M., Iskandar, N., Analisis kerusakan pada secondary superheater tube di sistem boiler pada power plant akibat proses soot blowing. Rotasi, 24(4), 41 – 48, 2022.

Saputro, I.T., Nurbanasari, M., Analisis kegagalan secondary superheater tube pada PLTU batubara kapasitas 600 MW, G-Tech: Jurnal Teknologi Terapan, 7(2), 474 – 483, 2023.

Septian, B., Aziz, A., Rey, P.D. Desain dan rancang bangun alat penukar kalor (heat exchanger) jenis shell dan tube, Jurnal Baut dan Manufaktur, 3(1), 53 – 56, 2021.

Sukadi, Novarini, Analisa kegagalan pipa superheater pada boiler tipe pipa air. Teknika, 4(2), 113 – 116, 2017.

Suyatno, Riupassa, H., Bayani, A.J., Analisis perpindahan panas pada heat exchanger tipe TI47D menggunakan sirip duri bentuk kerucut, Jurnal Teknik Mesin, 6(2), 63-75, 2017.

Yaqin, R.I., Huda, M., Tumpu, M., Priharanto, Y.E., Siahaan, J.P., Demeianto, B., Priyambodo, B.H., Umar, M.L., Analisa perpindahan panas heat exchanger mesin induk (studi kasus: KM. Sumber Mutiara), Jurnal Teknologi Terapan, 8(1), 53 – 56, 2022.

Nulhakim, Uji unjuk kerja pendingin ruangan berbasis theroelectric cooling, Jurnal Simeteris, 8(1), 85-90, 2017.

Tan, G., Zhao, D., Study of thermoelectric space cooling system integrated with phase change material, Jurnal Applied Thermal Engineering, 86, 187-198, 2015.

Widianto, T.N., Hakim, A.R., Performansi pendingin termoelektrik alat transportasi ikan segar pada berbagai tegangan, Jurnal Agritech, 36(4), 485-490, 2016.

Widianto, T.N., Hermawan, W., Utomo, B.S.B., Uji coba peti ikan segar berpendingin untuk pedagang ikan keliling, Jurnal JPB Perikanan, 9(2), 185-191, 2014.




DOI: https://doi.org/10.29303/dtm.v14i1.761

Refbacks

  • There are currently no refbacks.


Copyright (c) 2024

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

 
After being re-accredited, the Journal of Dinamika Teknik Mesin, still has sinta 3 (S3) which is valid until 2025.
View My Stats