Kinerja mesin air water harvester dengan evaporator koil pada berbagai kecepatan udara masuk

M. Mirmanto, I.B. Alit, A. Maulana

Abstract


An experimental study regarding the performance of air water harvester was conducted at the natural ambient conditions. The air water harvester consisted of 3 coil evaporators and used R134a as the working fluid. The coil evaporators were constructed from copper tubes with a diameter of 6.35 mm, coil number of 26, and coil diameter of 8 cm. The air intake velocities were 4 m/s, 5 m/s, 6 m/s. The results show that the highest water mass is 1.72 kg for 7 hours at the air velocity of 6 /s, and the total heat transfer rate is 582 J/s. Increasing the air intake velocity raises the fresh water mass and the total heat transfer rate. Based on EUR the machine is not effective yet but based on the price of the water the machine gives benefit.


Keywords


Air-water harvester; Water mass; Total heat transfer rate; EUR

Full Text:

PDF

References


Ahmad, F.F., Ghenai, C., Al Bardan, M., Bourgon, M., Shanableh, A., Performance analysis of atmospheric water generator under hot and humid climate conditions: drinkable water production and system energy consumption. Case Studies in Chemical and Environmental Engineering, 6, 100270, 2023. https://doi.org/10.1016/j.cscee.2022.100270.

Dirgantara, R.P. Pengaruh posisi evaporator terhadap jumlah air yang dihasilkan dengan menggunakan sistem kompresi uap, Skripsi, Universitas Mataram, 2021.

Faroni, A., Pengaruh diameter pipa unit pengembun terhadap massa air yang pengaruh diameter pipa unit pengembun terhadap massa air yang dihasilkan dari air-water harvester, Skripsi Universitas Mataram, 2022.

Fauzan, M., kinerja mesin air water harvester dengan unitpengembun paralel pada berbagai kecepatan udara masuk, Skripsi, Universitas Mataram, Mataram, 2022.

Free online psychometric chart calculator. http://www.hvac-calculator.net/index.php?v=2,

Firdaus, L., Unjuk kerja mesin air-water harvester dengan unit pengembun shell-spiral pada berbagai kecepatan udara masuk, Skripsi, Universitas Mataram, 2022.

Incropera, F.P., Dewitt, D.P., Bergman, T.L., Lavine, A.S., Fundamental of heat and mass transfer, Sixth Edition, John Wiley and Sons, USA, 2006.

Mirmanto, M., Pangestu, A.D., Experimental heat transfer rate on vertical pipes of a simple water harvester. Journal of Heat and Mass Transfer, 33, 41–50, 2023.

Mirmanto, M., Syahrul, S., Wijayanta, A.T., Effect of Evaporator Diameters on Performances of a Custom Air Water Generator. Frontiers in Heat and Mass Transfer, 20, 6–10, 2023a. https://doi.org/10.5098/hmt.20.9

Mirmanto, M., Syahrul, S., Wijayanta, A.T., Mulyanto, A., Winata, L.A., Effect of evaporator numbers on water production of a free convection air-water harvester, Case Studies in Thermal Engineering, 72, 101253, 2021. https://doi.org/10.1016/j.csite.2021.101253

Mirmanto, M., Wirawan, M., Najib, A., Effect of capillary tube length on mass of water production. International Journal of Advances in Engineering and Management, 4(2), 210–216, 2022. https://doi.org/10.35629/5252-0402210216

Najib, A.A., Pengaruh variasi panjang pipa kapiler terhadap air yang dihasilkan dari udara menggunakan sistem kompresi uap, Skripsi Universitas Mataram, 2021.




DOI: https://doi.org/10.29303/dtm.v14i1.828

Refbacks

  • There are currently no refbacks.


Copyright (c) 2024

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

 
After being re-accredited, the Journal of Dinamika Teknik Mesin, still has sinta 3 (S3) which is valid until 2025.
View My Stats