Pengaruh sudut kemiringan atap seng dan plastik gelombang terhadap tingkat kebisingan akibat air hujan

I. Qiram, G. Rubiono

Abstract


Zinc and plastic roofs are used vary widely in poor society because of their low price and their installation easiness. A roof installation with an inclination angle is done in order to the rain water is easy to flow. Rainfall causes noise that has a bad impact to human. This research is aimed to obtaining the effect of inclination angle of zinc and plastic roofs on the noise intensity. The research was done experimentally. The roofs investigated consist of zinc and plastic roofs in waveforms. A room with an overall size of 80 cm x 80 cm x 150 cm was made of wood as the frame. The inclination angles were varied; 10o, 20o, 30o and 40o. The rainfall was modeled by a sprayer with three different water flow rates 0,8; 1,0 and 1,2 lt/s. These flow rates represented low, medium and heavy rains. The noise intensity was measured using a sound level meter, which was placed in the centre of the room. The result shows that increasing the roof inclination angle causes the noise intensity to decrease. The plastic roof has lower noise intensity than the zinc roof. Furthermore, the experimental noise intensity data are relatively safe according to the noise safety level.


Full Text:

PDF

References


Feidihal, 2007, Tingkat kebisingan dan pengaruhnya terhadap mahasiswa di bengkel Teknik Mesin Politeknik Negeri Padang, Jurnal Teknik Mesin Vol. 4 No. 1, p. 31-41, ISSN 1829-8958.

Fredianta D., Huda L.N., Ginting E., 2013, Analisis tingkat kebisingan untuk mereduksi dosis paparan bising di PT. XYZ, e-Jurnal Teknik Industri FT USU Vol 2, No. 1, p. 1-8.

Hopkins C., 2006, Rain noise from glazed and lightweight roofing, Information Paper 2/06, BRE Press, Garston, Watford.

Ikeda H., Yoshida T., Mimura K, 2002, Measuring and predicting rainfall noise-reduction effects of Shizuka-Ace®, Furukawa Review, No. 21, p. 81-86.

Jansen H.W., 2004, Rainfall and impact noise measurements on metal roof tiles, TNO Report, Sound and Vibration Division, Stieltjesweg 1, The Netherlands.

Kementrian Sosial RI dan Badan Pusat Statistik, 2012, Analisis data kemiskinan berdasarkan data pendataan Program Perlindungan Sosial (PPLS) tahun 2011.

Kristanto L., Sugiharto H, Atmojo AD, Loekito LBD, 2011, Studi reduksi bunyi pada material insulasi atap zincalume, DIMENSI (Journal of Architecture and Built Environment), Vol. 38, No. 2, p. 101-110, ISSN 0126 - 219X.

Munilson J., Edward Y., Al Hafiz, 2014, Gangguan pendengaran akibat bising: tinjauan beberapa kasus, Bagian Telinga Hidung Tenggorok Bedah Kepala Leher, Fakultas Kedokteran Universitas Andalas - RSUP Dr. M. Djamil Padang.

Rosadi H.E., Rismansyah N, Fuad F, Setiyowati E, 2012, Pengaruh sudut kemiringan atap bangunan dan orientasinya terhadap kualitas termal, Prosiding Temu Ilmiah IPLBI 2012.

Satwiko P., 2012. Renovasi akustik gedung konser pascasarjana Institut Seni Indonesia (PS-ISI) Yogyakarta. Jurnal Arsitektur Komposisi. 10(2):119-132.

Sembiring EL, Surbakti MS, 2013, Analisis kebisingan akibat arus lalu lintas di jalan gagak hitam (ring road) medan dan tingkat ketergangguan masyarakat, Teknik Sipil, Universitas Sumatera Utara, Medan.

Setiawan M.F., 2010, Tingkat kebisingan pada perumahan di perkotaan, Jurnal Sipil & Perencanaan 12(2): 191-200.

Sunarsih E., 2014, Rumah sehat, Kesehatan Lingkungan Pemukiman, Fakultas Kesehatan Masyarakat, Universitas Sriwijaya.

Tukidi, 2010, Karakter curah hujan di indonesia, Jurnal Geografi, Vol. 7 No. 2.

Wafiroh A.H., 2013, Pengukuran tingkat kebisingan di lingkungan SMPN 2 Jember, Skripsi, Jurusan Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Jember

Wardle Storeys Blackburn Ltd, 2008, Reducing rain noise on profiled metal roofing systems using DEDPAN ® DS2020 RDV, Durbar Mill, Hereford Road, Blackburn Lancashire BB1 3JU England.

Yermadona H., Yossyafra, Kurniati T, 2013, Pengaruh penerapan zona selamat sekolah terhadap tingkat kebisingan lalu lintas di kawasan sekolah kota Padang, TeknikA Vol. 20 No. 2, p. 45-52.

Zikri A., 2014, Struktur atap, Arsitektur Unimal, Lhokseumawe.




DOI: https://doi.org/10.29303/dtm.v6i2.12

Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 Dinamika Teknik Mesin

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

 
After being re-accredited, the Journal of Dinamika Teknik Mesin, still has sinta 3 (S3) which is valid until 2025.
View My Stats