PENGARUH SUSUNAN PIPA LALUAN TERHADAP PEMANFAATAN KALOR PADA KOLEKTOR SURYA PELAT DATAR ABSORBER GRANITE

Made Wirawan, M. Mirmanto, I Gede Bawa Susana, Rudy Sutanto

Abstract


The collector of solar energy can be used for heating fluidssuch as liquid or gas. The  optimize  absorbtion of solar energy depends on the collectordimention and component, e.g.the width, body of collector, tube formation, cover and isolation system. This research usesa granite absorber with a variation of tube formations and water flow rates. The aim of the research is tofind out the optimal tube formation.

To achieve the aim of the research,theexperiments of water heating usingthree collectorswith a granite absorber 80 Cm x 100 Cm and three way tube formatians have been done.The variation of water flow rates had beenperformed toinvestigate the maximal performance. The water flow rates used were200, 250 and 300 cc/minute.

The result of research achieved value of heat utilization of solar collector influenced by: arrangement inlet tube, flow rates of water and time. The maksimal heat utilization occur at parallel 7 for each flow rate. The flow rate 300 cc/minute show maximal heat utilization.


Full Text:

PDF

References


Stefanovic Velimir P. And Bojic Milorad Lj, 2006, Development And Investigation Of Solar Collectors For Conversion Of Solar Radiation Into Heat And/Or Electricity.Thermal Science: Vol. 10 (2006), Suppl., No. 4, Pp. 177-187

Wirawan Made dan Rudy Sutanto, 2011,Analisa Laju Perpindahan Panas Pada Kolektor Surya Tipe Pelat Datar Dengan Absorber Pasir.Jurnal Dinamika Teknik Mesin, Volume 1. Nomor 2 Edisi Juli 2011, hal. 65-72.

Kalogirou. Soteris., 2009 ;Solar Energy Engineering: Processes and Systems 1st Edition, British Library, USA.


Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 Dinamika Teknik Mesin

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

 
After being re-accredited, the Journal of Dinamika Teknik Mesin, still has sinta 3 (S3) which is valid until 2025.