Pengaruh sudut alur sekat terhadap unjuk kerja menara pendingin (cooling tower)

A. Ardani, I. Qiram, G. Rubiono

Abstract


Cooling tower is an equipment that use to decrease water temperature by extracting heat and emitting it to atmosphere. Cooling tower buffle is an important component that effect water flow. This research is aimed to get the effect of cooling tower buffle due to its performance which are range, heat transfer rate and efficiency. The research is done by experiment. Cooling tower buffle are varied in plot angle which are 5o, 10o, 15o dan 20o. Water volume flow rate are varied as 50, 75, 100 and 125 ml/s. Inlet water tempersatur are varied as 50o, 60o and 70oC. The measurements are done for water and air temperature at inlet and outlet points. The result shows that buffle plot angle has effect due to cooling tower performance.

Keywords


Cooling tower; Buffle plot angle; Range; Performance

Full Text:

PDF

References


Effendi A, Wirza R, 2013. Perencanaan Sistem Scada Cooling Tower Menggunakan Siemens Simatic Step 7 dan Wincc, Jurnal Teknoif 1(1): 6-14

Fuhaid N, 2008, Pengaruh Sudut Kemiringan Sekat Terhadap Unjuk Kerja Menara Pendingin Air, Widya Teknika 16(2): 45-53

Johanes S, 2010, Karakteristik Menara Pendingin dengan Bahan Isian Ijuk, Forum Teknik 33(3): 188-194

Johanes S, 2011a, Karakteristik Menara Pendingin Dengan Bahan Isian Tali Ijuk, Jurnal Teknologi Technoscientia 4(1): 103-113

Johanes S, 2011b, Komparasi Karakteristik Menara Pendingin Menggunakan Beberapa Tipe Susunan Pipa-pipa Sebagai Pendistribusi Cairan, Forum Teknik 34(1): 67-75

Mayur AR, 2014, Performance Improvement of Natural Draft Cooling Tower, International Journal of Engineering Research and Reviews (IJERR) 2(1): 7-15

Patel K, Mohite NV, 2015, Experimental Investigation of Forced Draft Counter Flow Cooling Tower with Twisted Tape Insert: Horizontal & Vertical, International Journal on Recent and Innovation Trends in Computing and Communication 3(5): 2795-2798

Pratiwi NP, Nugroho G, Hamidah NL, 2014, Analisa Kinerja Cooling Tower Induced Draft Tipe LBC W-300 Terhadap Pengaruh Temperatur Lingkungan, Jurnal Teknik Pomits 7(7): 1-6

Qian J, Li L, Tan Y, Zheng D, 2012, Research and Application of Closed Cooling Tower, 2nd International Conference on Electronic & Mechanical Engineering and Information Technology: 2213-2215

Taufik HA, Listyadi SD, Sutjahjono H, 2014, Analisis Beban Kalor Cooling Tower Induced Draft Counterflow Dengan Bahan Pengisi Bambu Wulung, Artikel Ilmiah Hasil Penelitian Mahasiswa, Jurusan Teknik Mesin. Fakultas Teknik, Universitas Jember

UNEP, Menara Pendingin, Pedoman Efisiensi Energi Untuk Industri di Asia, www.energy efficiencyasia.org, diakses 20 April 2017

Yadav BK, Soni SL, 2015, Experimental Study of the Performance of Cooling Tower, International Journal of Science and Research (IJSR) 4(8): 2035-2038

Wibisono Y, 2005, Perbandingan Unjuk Kerja Antar Bahan Pengisi Pada Menara Pendingin Tipe Induced Counter Flow, Jurnal Teknologi Pertanian 6(3): 152 - 162




DOI: https://doi.org/10.29303/dtm.v8i1.136

Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 Dinamika Teknik Mesin

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

 
After being re-accredited, the Journal of Dinamika Teknik Mesin, still has sinta 3 (S3) which is valid until 2025.
View My Stats